                                  This is the web edition of the original ⮫ AC500-S safety user manual, version 1.3.2. This web edition is provided for quick reference only. The original safety user manual must be used to meet functional safety application requirements.  | 
                           
| 
                                  Name  | 
                              
                                  Data type  | 
                              
                                  Description  | 
                           
|---|---|---|
| 
                                  S1_S_EStopIn  | 
                              
                                  BOOL  | 
                              
                                  Emergency stop button S1  | 
                           
| 
                                  S2_MutingSwitch11  | 
                              
                                  BOOL  | 
                              
                                  Muting sensor S2  | 
                           
| 
                                  S3_MutingSwitch12  | 
                              
                                  BOOL  | 
                              
                                  Muting sensor S3  | 
                           
| 
                                  S4_MutingSwitch21  | 
                              
                                  BOOL  | 
                              
                                  Muting sensor S4  | 
                           
| 
                                  S5_MutingSwitch22  | 
                              
                                  BOOL  | 
                              
                                  Muting sensor S5  | 
                           
| 
                                  S6_S_GuardSwitch  | 
                              
                                  BOOL  | 
                              
                                  Door switch S6 with two contacts  | 
                           
| 
                                  S7_S_AOPD_In  | 
                              
                                  BOOL  | 
                              
                                  OSSD from light curtain S7  | 
                           
| 
                                  K1_EDM  | 
                              
                                  BOOL  | 
                              
                                  Feedback from external device K1 (actuator)  | 
                           
| 
                                  K2_EDM  | 
                              
                                  BOOL  | 
                              
                                  Feedback from external device K2 (actuator)  | 
                           
| 
                                  S9_Reset  | 
                              
                                  BOOL  | 
                              
                                  Reset safety demand by user S9  | 
                           
| 
                                  S0_Reset  | 
                              
                                  BOOL  | 
                              
                                  Reset error by user S0 (derived from functional application)  | 
                           
| 
                                  ApplCtrl1  | 
                              
                                  BOOL  | 
                              
                                  Signal controlling the actuator, enabled by safety loop (derived from functional application)  | 
                           
| 
                                  StartTest_LC1  | 
                              
                                  BOOL  | 
                              
                                  Signal starting test of light curtain S7 (derived from functional application)  | 
                           
| 
                                  ApplMutingEnable1  | 
                              
                                  BOOL  | 
                              
                                  Signal enabling start of the muting sequence (derived from functional application)  | 
                           
| 
                                  Name  | 
                              
                                  Data type  | 
                              
                                  Description  | 
                           
|---|---|---|
| 
                                  S_EDM_Out_K  | 
                              
                                  BOOL  | 
                              
                                  Drives actuator via K1 and K2  | 
                           
| 
                                  S_MutingActive_L1  | 
                              
                                  BOOL  | 
                              
                                  Drives muting lamp L1  | 
                           
| 
                                  S_TestOut_LightCurtain_S8  | 
                              
                                  BOOL  | 
                              
                                  Test output for light curtain S8  | 
                           
| 
                                  Errors  | 
                              
                                  BOOL  | 
                              
                                  Represents all errors of the used FB (connected to functional application)  | 
                           
| 
                                  DiagCodes  | 
                              
                                  WORD  | 
                              
                                  Represents all diagnostic codes of the used FB (connected to functional application)  | 
                           
| 
                                  TestPossible_LC1  | 
                              
                                  BOOL  | 
                              
                                  Indicates to the functional application that an automatic sensor test of the light curtain is possible.  | 
                           
| 
                                  TestExecuted_LC1  | 
                              
                                  BOOL  | 
                              
                                  Indicates to the functional application the successful execution of an automatic sensor test of the light curtain.  | 
                           
| 
                                  Name  | 
                              
                                  Data type  | 
                              
                                  Description  | 
                           
|---|---|---|
| 
                                  S_SafeControl  | 
                              
                                  BOOL  | 
                              
                                  Indicates the status of the safety guards (TRUE = safety enabled)  |